Multi-Para. Patient Monitor
Item#:W00001853
Brand:EHSY
Origin:China
Description Tech Specs Shipping Detail Certification Accessories
Westingarea supplied high quality Multi-Para. Patient Monitor has the excellent performance displayed as:
20 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titration table;
Efficient resistance to interference of defibrillator and electrosurgical cautery;
SPO2 can testing for 0.1% Weak;
RA-LL impedance Respiration;
Trend Coexist Display;
OxyCRG DyNamic View Display;
Bed to Bed view Display;
Networking capacity and nurse_calling system;
Options of printing, IBP, VGA and EtCO2;
UP to 4 hours working capacity of built_in rechargeable battery;
10.4"high resolution color TFT LCD display;
Large volume of tabular and graphic trends information storage and easy to recall;
Anti-ESU, anti- defibrillator;
Capture dynamic waveforms.
Item: | Multi-Para. Patient Monitor | |
ECG: | Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V),Lead selection: I, II, III, avR, avL, avF, V, ,Waveform: 2 ch,Lead mode: 3 Leads ( R, L, F or RA, LA, LL),Lead selection: I, II, III, ,Waveform: 1 ch,Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto | |
HR and Alarm: | Range:Adult: 15 ~ 300 bpm,Neo/Ped: 15 ~ 350 bpm, Accuracy: ± 1% or ± 1bpm,which great, Resolution: 1 bpm, Sensitivity: > 200 (uV P-P), Differential Input Impedance: > 5 MΩ, CMRR:Monitor: > 105 dB, Operation: > 105 dB, Diagnosis: > 85 dB, Electrode offset potential: ±300mV, Leakage Current: < 10 uA, Baseline Recovery: < 3 S After Defi, ECG Signal Range: ±8 m V ( Vp-p ):Bandwidth: Surgery: 1 ~ 15 Hz, Monitor: 0.5 ~ 35 Hz, Diagnostic: 0.05 ~ 100 Hz, Calibration Signal: 1 (mV p-p), Accuracy:±5%, ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV, ARR Detecting: Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC | |
Alarm: | Available | |
Review: | Available | |
RESPARATION: | Method: Impedance between R-F(RA-LL),Differential Input Impedance: >2.5 MΩ,Measuring Impedance Range: 0.3~5.0Ω,Base line Impedance Range: 0 – 2.5KΩ, Bandwidth: 0.3 ~ 2.5 Hz, Measuring and Alarm Range: Adult: 0 ~ 120 rpm,Neo/Ped: 0 ~ 150 rpm,Resolution: 1 rpm, Accuracy : ±2 rpm, Apean Alarm: 10 ~ 40 S | |
NIBP: | Method: Oscillometric,Mode: Manual, Auto, STAT,Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min),Measuring Period in STAT Mode: 5 Min, Pulse Rate Range: 40 ~ 240 bpm, Alarm Type: SYS, DIA, MEAN | |
Measuring and alarm range: | Adult Mode: SYS: 40 ~ 270 mmHg, DIA: 10 ~ 215 mmHg, MEAN: 20 ~ 235 mmHg, Pediatric Mode: SYS: 40 ~ 200 mmHg, DIA: 10 ~ 150 mmHg, MEAN:20 ~ 165 mmHg, Neonatal Mode: SYS: 40 ~ 135 mmHg, DIA:10 ~ 100 mmHg, MEAN:20 ~ 110 mmHg, Resolution Pressure:1mmHg, Accuracy Pressure Maximum Mean error: ±5mmHg, Maximum Standard deviation: ±8mmHg, Overpressure Protection: Adult Mode: 297±3 mmHg, Pediatric Mode: 240±3 mmHg, Neonatal Mode: 147±3 mmHg | |
SpO2: | Measuring Range: 0 ~ 100 %, Alarm Range: 0 ~ 100 %, Resolution: 1 %, Accuracy: 70% ~ 100% ±2 %, 0% ~ 69% unspecified, Actualization interval: about 1 Sec, Alarm Delay: 10 Sec, Pulse Rate: Measuring and Alarm Range: 20~300bpm, Resolution: 1bpm, Accuracy: ±2bpm | |
Temperature: | Channel: 1, Measuring and Alarm Range: 0 ~ 50 °C, Resolution: 0.1°C, Accuracy: ±0.1°C, Actualization interval: about 1 Sec, Average Time Constant :< 10 Sec. | |
IBP: | Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2, Measuring and alarm range, ART: 0 ~ 300 mmHg, PA: -6 ~ 120 mmHg, CVP/RAP/LAP/ICP: -10 ~ 40 mmHg, P1/P2: -10 ~ 300 mmHg | |
Press Sensor, Sensitivity: | 5 uV/V/mmHg, Impedance: 300-3000Ω, Resolution: 1 mmHg, Accuracy: ±2% or ±1mmHg, which great, Actualization interval: about 1 Sec. |
Dimension: | 320×160×270mm | |
Net Weight : | <5kg | |
Gross Weight: | <8kg | |
Package Size: | 445×285×365mm |
ISO9001 ISO13485
No Accessories!