Navigation Products
- Oscilloscopes
- Multimeters
- Safety Testers
- Component Parameter Testers
- Audio Device Testers
- Electrical Parameter Testers
- Signal Generators
- Electroacoustics Testers
Recommended Products
>>MORE
You have looked
Real-time Signal Analyzer
Item#:W00001722
Brand:EHSY
Origin:China
Description Tech Specs Shipping Detail Certification Accessories
FEATURES
A pocket real-time noise signal analyzer
Real-time octave (and 1/3 octave) band analyses
FFT analysis on noise or vibration
Lower background noise, 90dB linearity range
Comply with IEC 61672 class 1 and IEC 61260 class 1
Different software could be select based on your specific needs
USES
Comprehensive sound measurements
Environment noise certification and 24h monitoring
Noise profile measurement of industrial noise
Gathering field-data for further analyses
Quality-testing of products
Research and development
A pocket real-time noise signal analyzer
Real-time octave (and 1/3 octave) band analyses
FFT analysis on noise or vibration
Lower background noise, 90dB linearity range
Comply with IEC 61672 class 1 and IEC 61260 class 1
Different software could be select based on your specific needs
USES
Comprehensive sound measurements
Environment noise certification and 24h monitoring
Noise profile measurement of industrial noise
Gathering field-data for further analyses
Quality-testing of products
Research and development
Item: | Real-time Signal Analyzer | |
Bundled Software: | Class1,statistical analysis software | |
Connector: | X9 - 6Z, also LEMO socket; | |
Signal Input Impedance: | 150 kΩ //100 pF; | |
The Max. Input Voltage: | 10 V(RMS); | |
Input Protection: | ± 18 V(RMS). | |
Frequency Range: | 10 Hz ~ 20 kHz ± 0.2 dB, 1 Hz ~ 23 kHz (± 1.0 dB) | |
Range Gain: | -10 dB, 0 dB, 10 dB, 20 dB, 30 dB, 40 dB. | |
Range Error: | ≤0.1 dB. | |
Self-generated Noise Voltage: | <4μV (1 Hz~23 kHz) | |
Measuring Voltage Range: | 15 μV ~ 10 V (RMS). | |
Signal Output: | ||
Connector: | Stereo Connector; | |
Output Impedance: | 1 k Ω ; | |
Max Output Signal Voltage: | 3.2 V. | |
Level Linearity Range: | >90 dB. | |
A/D Bits: | 24 bits. | |
Sampling Frequency: | 48 kHz. | |
Anti-aliasing Filter: | Cutoff frequency is 23.5 kHz and stopband attenuation is 100 dB. | |
Display: | 240×160 graphic LCD, with EL background lighting. | |
Contrast Adjustment: | 64-class adjustable. | |
Output Interface: | RS 232 interface, which can be connected to the mini-printer to print the measuring result, or connected to PC to transfer the measuring result and real-time analysis result; | |
USB Interface, mini B type. Complying with USB 1.1, compatible with USB 2.0, which can transfer the measuring result to PC, or the Flash disk. : |
||
Power Supply: | 4×LR6 alkaline battery or rechargeable batteries, which can work for over 8 hours continuously. 5 V external power supply is also acceptable. | |
Data Storage: | . The measuring result can be saved in 256 kB Flash, or transferred to the Flash disk through USB interface. | |
Internal Clock: | Error less than 1 min/month. | |
Measuring point names could be entered enter into the analyzer in English. : |
||
The analyzer can store 256 calibration records. : |
||
Starting Time: | <10 s. | |
Dimensions: | 210 × 90 × 38 (mm). | |
Weight: | 0.5 kg. (include batteries) | |
Electromagnetic Compatibility: | Comply with the requirements of IEC 61672 on X type sound level meter. | |
Working Environment: | | |
Working Temperature: | -10 ~ 50 ℃ | |
Storing Temperature: | -20 ~ 70 ℃ | |
Relative Humidity: | 25 ~ 90 % |
This item does not require any certification.
No Accessories!