Calorimeter (Double Control)
Item#:W00005355
Brand:EHSY
Origin:China
Description Tech Specs Shipping Detail Certification Accessories
1. All measured data are real and reliable. Software correction is no need.
2. Highly automated instrument; can automatically recognize oxygen bomb, fix the quality of water, control temperature and carry out the test.
3. Strong adaptive capacity to environment; the testing results will not be affected by the fluctuation of the ambient temperature.
4. The isothermal points with helix tube technology (Patent No. 200610031417.X,200610031414.6) realized temperature consensus of every part of the external barrel and barrelhead quickly, temperature of any fixed point can exactly represent that of the external barrel and barrelhead, making sure the test results are accurate.
5. The application of power contravariance and purification technology makes sure the instrument will not be affected by large variation of power voltage or power frequency.
6. Simple installation and debugging, easy to control.
7. Multiple controls by one computer and the inter-testing activity will not mutually affect.
8. Dada processing works in parallel with testing; easy for the users to look up test data.
9. Networking and the balance interlocking are possible.
2. Highly automated instrument; can automatically recognize oxygen bomb, fix the quality of water, control temperature and carry out the test.
3. Strong adaptive capacity to environment; the testing results will not be affected by the fluctuation of the ambient temperature.
4. The isothermal points with helix tube technology (Patent No. 200610031417.X,200610031414.6) realized temperature consensus of every part of the external barrel and barrelhead quickly, temperature of any fixed point can exactly represent that of the external barrel and barrelhead, making sure the test results are accurate.
5. The application of power contravariance and purification technology makes sure the instrument will not be affected by large variation of power voltage or power frequency.
6. Simple installation and debugging, easy to control.
7. Multiple controls by one computer and the inter-testing activity will not mutually affect.
8. Dada processing works in parallel with testing; easy for the users to look up test data.
9. Networking and the balance interlocking are possible.
Item: | Calorimeter (Double Control) | |
Single Complete Testing Duration: | <11min | |
Stability: | Heat Capacity Variation in 3 months: ≤0.20% | |
Accuracy: | The mean value and standard value deviation is less than 50J/g after 5 caloric value test of benzoic acid. | |
Temperature Resolution: | 0.0001K | |
the Water Weight of External Barrel: | 40kg | |
Oxygen Bomb,Identification: | Automatic | |
Self-diagnostic Function: | Yes | |
Max Power: | 1.5kW | |
Mainframe Size: | 432×560×393mm | |
Precision: | RSD≤0.1% | |
Ambient Temperature: | The test results confirm to demands when temperature during(10-30)℃ | |
Max Test Range: | 42000J /g | |
Sample Weight: | 0.5-1.5g | |
New type of Oxygen Bomb: | Yes | |
CAN Bus Interface: | Yes | |
Complete Appliance Crust Shaped: | Yes | |
Voltage: | AC220±10% 50Hz±1Hz | |
Net Weight: | 60kg |
This item does not require any certification.
No Accessories!