Gas Chromatograph
Item#:W00001461
Brand:SYSBERY
Origin:China
Description Tech Specs Shipping Detail Certification Accessories
1. Trace toxics analysis, monitoring and research in environmental protection, atmosphere and water source pollution
2. Biochemistry, clinic application, pathology and toxicology research
3. Microorganism analysis and research in food ferment, and microelements analysis in beverage
4. Intermediate and finished product analysis in Chinese and western medicine materials
5. Crude oil composition analysis and control in petroleum processing, petrochemical industry, petroleum geological industry, and geological prospecting research
6. Component research and production control in organic chemistry and organic synthesis
7. Analysis and research in sanitary quarantine, labor protection, and hazard detection
8. Monitoring, control and research in cutting-edge science and military technologies.
Features
1. Newly designed, high performance HRGC
2. Double FID detectors in the basic type with wide accessory options such as GC122-TCD thermal conductivity detector, GC122-ECD electron capture detector, GC122-NPD nitrogen and phosphorous detector, GC122-FPD flame photometric detector, converter, gas sample inlet valve, etc.
3. In the basic type, the instrument has dual packed columns, double samplers and dual gas path system structure, which can effectively restrain baseline fluctuation and drift in real time, suitable for temperature programming analysis. The instrument can work with three types of detectors at the same time. With different detector combination in different application, the instrument can support detectors working in either cascade or paralleled connection.
4. The instrument in the basic type is equipped with completed capillary analysis system and independent capillary split sampler, which includes diaphragm cleaning, split flow and auxiliary gas adjustment. It supports capillary split / splitless sampler, cold on-column sampler, and
5. The gas path of the instrument adopts high precision scale flow control valve, unloading valve and needle valve. It’s easy to adjust flow capability and has better reproducibility and stability.
6. The instrument supports following injection
7. The instrument supports following injection methods.
8. Packed column: on-column sample injection, nstantaneous vaporizing sample injection, gas sample injection.
9. Capillary column: split injection, split less injection, large diameter column direct injection.
10. Newly developed computer aided temperature control system. It can manage the temperature control of six path heating areas at the same time, including column, ion chamber, thermal conductivity detector, capillary column sampler, packed column sampler auxiliary and standby, with high precision (less than ±
11. The column has five –phase programmed temperature control, and the highest heating rate is up to
12. The system has such functions as switch-off protection, temperature limit setup, temperature scanning, rapid automatic cooling, i.e. Back opening door, and etc.
13. Large volume full lens stainless column (
Item: | Gas Chromatograph | |
1. Temperature control range: | 7℃-400℃ of room temperature (increment by 1℃) | |
2. Temperature control objects: | column, ion chamber, thermal conductivity, sampler A, sample B, auxiliary (standby) | |
3. Temperature programming phase: | five | |
4. Temperature programming rate: | 0.1℃-40℃/min(increment by 0.1) | |
Flame lonization Detector (FID) : |
||
1. Sensitivity: | M≤1×10-11g/s(sample: C16) | |
2. Optimal test result: | M≤5×10-12g/s | |
3. Baseline noise: | ≤5×10-14A | |
4. Baseline drift: | ≤6×10-13A/h | |
5. Linear range: | ≥10E6 |