Westingarea supply high quality Chemistry Analyzer.
Specifications∶
·nalysis Method: endpoint, rate, two-point, single-wavelength, dual-wavelength, blank reagent, blank sample and absorbency. Calculating method, such as factor, single-point
calibration and dual-point calibration, etc., is also available
·Light Source: long-life halogen lamp, 6V/12W
·Wavelength Range: 340~630nm, optional
·Filter: 7 basic filters: 340,380,405,510,545,578,630nm
2 optional filters
·Accuracy of central wavelength:±3nm
·Resolving Power: Display: 0.001Abs; Inner calculate: 0.0001 Abs
·Slope Error: ≤5% Sway:0.003A/h
·Colorimetric Tank: 10mm 35μL , quartz /stainless steel floating colorimetric tank.
·Temperature Control: Room temperature, 25℃,30℃,37℃, (±0.1℃variable)
·Sampling Volume: 200μL~ 3000μL settable, recommended: 500μL
·Cross Contamination: <1.0% Repeat: <1.0%
·Control: Computer controls the analyzer. Bidirectional communication is available
·Memory: up to 200 items and 100 thousand test results
·Display: Connected to external colorful LCD. Reaction curve is displayed at real time.
·Test Report: 3 standard formats for selection
·Output: RS232, connected to external standard PC
·Ambient Condition: Room temperature: 10 ℃~ 30℃,Humidity: ≤80%
·Power: AC 220×(1±10%)V,(50±1)Hz
·Atmosphere Pressure: 75kPa~106kPa
·nalysis Method: endpoint, rate, two-point, single-wavelength, dual-wavelength, blank reagent, blank sample and absorbency. Calculating method, such as factor, single-point
calibration and dual-point calibration, etc., is also available
·Light Source: long-life halogen lamp, 6V/12W
·Wavelength Range: 340~630nm, optional
·Filter: 7 basic filters: 340,380,405,510,545,578,630nm
2 optional filters
·Accuracy of central wavelength:±3nm
·Resolving Power: Display: 0.001Abs; Inner calculate: 0.0001 Abs
·Slope Error: ≤5% Sway:0.003A/h
·Colorimetric Tank: 10mm 35μL , quartz /stainless steel floating colorimetric tank.
·Temperature Control: Room temperature, 25℃,30℃,37℃, (±0.1℃variable)
·Sampling Volume: 200μL~ 3000μL settable, recommended: 500μL
·Cross Contamination: <1.0% Repeat: <1.0%
·Control: Computer controls the analyzer. Bidirectional communication is available
·Memory: up to 200 items and 100 thousand test results
·Display: Connected to external colorful LCD. Reaction curve is displayed at real time.
·Test Report: 3 standard formats for selection
·Output: RS232, connected to external standard PC
·Ambient Condition: Room temperature: 10 ℃~ 30℃,Humidity: ≤80%
·Power: AC 220×(1±10%)V,(50±1)Hz
·Atmosphere Pressure: 75kPa~106kPa
Features∶
·Close Light Path System
·Long-life Halogen Lamp
·Large Memory
·Multifunctional Software
·Covenient Daily Maintenance
·Close Light Path System
·Long-life Halogen Lamp
·Large Memory
·Multifunctional Software
·Covenient Daily Maintenance
G.W(kg): 9
N.W(kg): 5.5
Dimension: 330 x 310 x 175mm
Dimension: 330 x 310 x 175mm
Carton size(mm)(L*H*M): 558×458×308
Spc.: 0.07CBM
Item: | Chemistry Analyzer | |
Analysis Method: | endpoint, rate, two-point, single-wavelength, dual-wavelength, blank reagent, blank sample and absorbency. Calculating method, such as factor, single-point calibration and dual-point calibration, etc., is also available | |
Light Source: | long-life halogen lamp, 6V/12W | |
Wavelength Range: | 340~630nm, optional | |
Filter: | 7 basic filters: 340,380,405,510,545,578,630nm; 2 optional filters | |
Accuracy of central wavelength: | ±3nm | |
Resolving Power: | Display: 0.001Abs; Inner calculate: 0.0001 Abs | |
Slope Error: | ≤5% Sway:0.003A/h | |
Colorimetric Tank: | 10mm 35μL , quartz /stainless steel floating colorimetric tank. | |
Temperature Control: | Room temperature, 25℃,30℃,37℃, (±0.1℃variable) | |
Sampling Volume: | 200μL~ 3000μL settable, recommended: 500μL | |
Cross Contamination: | <1.0% (Repeat <1.0%) | |
Control: | Computer controls the analyzer. Bidirectional communication is available | |
Memory: | up to 200 items and 100 thousand test results | |
Display: | Connected to external colorful LCD Reaction curve is displayed at real time. | |
Test Report: | 3 standard formats for selection | |
Output: | RS232, connected to external standard PC | |
Ambient Condition: | Room temperature (10 ℃~ 30℃),Humidity(≤80%) | |
Power: | AC 220×(1±10%)V,(50±1)Hz | |
Atmosphere Pressure: | 75kPa~106kPa |
G.W(kg): | 9 | |
N.W(kg): | 5.5 | |
Dimension: | 330 x 310 x 175mm | |
Carton size(mm)(L*H*M): | 558×458×308 | |
Spc.: | 0.07CBM |