Auto Biochemistry Analyzer
Item#:W00002294
Brand:EHSY
Origin:China
Description Tech Specs Shipping Detail Certification Accessories
Westingarea supply high quality Auto Biochemistry Analyzer.
Specifications∶
·Assay methods: End Point, Kinetic, Fix time etc.
·Principle: Photoelectric Colorimetry
·Light Source: Halogen lamp 12V/20W
·Photometry range: 0~3Abs
·Resolution: 0.0001Abs
·Wavelength: 10 wavelengths optional (340nm~800nm)
·Throughput: 400 tests/hour
·Reagent tray: 60 reagent positions
·Sample tray: 45 sample positions
·Reaction tray: 120 reaction positions
·Sample volume: 2~100ul, with 0.1ul increment
·Reagent volume: R1:10~500ul, R2: 10~500ul, with 0.5ul increment
·Minimum reaction volume: 150ul
·Maximum reaction time: 10 minutes
·Water Consumption: 3L/hour under working status
·Clean unit: 8-step auto-washing system
·Calibration: Calibration reset, select best test point by reaction curve without second
calibration
·Control rules: Westgard multi-rule, Cumulative sum check, Twin plot
·Temperature control: incubator 37±0.1℃
·Power supply: AC110/230(1±10%)V, 50/60Hz, 500VA
·Ambient: Operating temperature: 10~30℃
Relative humidity: ≤85%
Atmospheric pressure: 86~106kPa
·Assay methods: End Point, Kinetic, Fix time etc.
·Principle: Photoelectric Colorimetry
·Light Source: Halogen lamp 12V/20W
·Photometry range: 0~3Abs
·Resolution: 0.0001Abs
·Wavelength: 10 wavelengths optional (340nm~800nm)
·Throughput: 400 tests/hour
·Reagent tray: 60 reagent positions
·Sample tray: 45 sample positions
·Reaction tray: 120 reaction positions
·Sample volume: 2~100ul, with 0.1ul increment
·Reagent volume: R1:10~500ul, R2: 10~500ul, with 0.5ul increment
·Minimum reaction volume: 150ul
·Maximum reaction time: 10 minutes
·Water Consumption: 3L/hour under working status
·Clean unit: 8-step auto-washing system
·Calibration: Calibration reset, select best test point by reaction curve without second
calibration
·Control rules: Westgard multi-rule, Cumulative sum check, Twin plot
·Temperature control: incubator 37±0.1℃
·Power supply: AC110/230(1±10%)V, 50/60Hz, 500VA
·Ambient: Operating temperature: 10~30℃
Relative humidity: ≤85%
Atmospheric pressure: 86~106kPa
Features∶
·24 hour non-stop water cycle cooling system to ensure reagent at 2-8℃
·Dual-unattached durable ceramic syringes to ensure accuracy & precision
·Collision protection in both vertical and horizontal directions, stop & alarm automatically
once touching barrier, not affect former tests
·Automatic eligible cuvettes detection & selection
·Select best test point by reaction curve, create new factor automatically
·High accurate optical system
·Support LIS interface
·24 hour non-stop water cycle cooling system to ensure reagent at 2-8℃
·Dual-unattached durable ceramic syringes to ensure accuracy & precision
·Collision protection in both vertical and horizontal directions, stop & alarm automatically
once touching barrier, not affect former tests
·Automatic eligible cuvettes detection & selection
·Select best test point by reaction curve, create new factor automatically
·High accurate optical system
·Support LIS interface
Item: | Auto Biochemistry Analyzer | |
Assay methods: | End Point, Kinetic, Fix time etc. | |
Principle: | Photoelectric Colorimetry | |
Light Source: | Halogen lamp 12V/20W | |
Photometry range: | 0~3Abs | |
Resolution: | 0.0001Abs | |
Wavelength: | 10 wavelengths optional (340nm~800nm) | |
Throughput: | 400 tests/hour | |
Reagent tray: | 60 reagent positions | |
Sample tray: | 45 sample positions | |
Reaction tray: | 120 reaction positions | |
Sample volume: | 2~100ul, with 0.1ul increment | |
Reagent volume: | R1 (10~500ul), R2 (10~500ul), with 0.5ul increment | |
Minimum reaction volume: | 150ul | |
Maximum reaction time: | 10 minutes | |
Water Consumption: | 3L/hour under working status | |
Clean unit: | 8-step auto-washing system | |
Calibration: | Calibration reset, select best test point by reaction curve without second calibration | |
Control rules: | Westgard multi-rule, Cumulative sum check, Twin plot | |
Temperature control: | incubator 37±0.1℃ | |
Power supply: | AC110/230(1±10%)V, 50/60Hz, 500VA | |
Ambient: | Operating temperature: 10~30℃ | |
Relative humidity: | ≤85% | |
Atmospheric pressure: | 86~106kPa |
CE