Product
Brand
Brand | Product Name | EHSY Item# | Description | List Price(USD) | ||||||||||
EHSY | Patient Monitor | W00005100 |
Weight: Mo 4.1kg, MOA 3.9kg Display: 10.4'TFT LCD, Resolution 800&600 dots |
|||||||||||
EHSY | Patient Monitor | W00005099 |
Size: 322mm*150mm*285mm Weight:3.6kg Operation environment: temperature: 5~40℃, Humidity: 25%~93%(non-condensing), Power: AC100~240V, 50/60Hz Display: 10.4’ color TFT, Resolution 800&600 dots |
|||||||||||
EHSY | Multi-Para. Patient Monitor | W00001853 |
ECG:Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V),Lead selection: I, II, III, avR, avL, avF, V, ,Waveform: 2 ch,Lead mode: 3 Leads ( R, L, F or RA, LA, LL),Lead selection: I, II, III, ,Waveform: 1 ch,Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto HR and Alarm:Range:Adult: 15 ~ 300 bpm,Neo/Ped: 15 ~ 350 bpm, Accuracy: ± 1% or ± 1bpm,which great, Resolution: 1 bpm, Sensitivity: > 200 (uV P-P), Differential Input Impedance: > 5 MΩ, CMRR:Monitor: > 105 dB, Operation: > 105 dB, Diagnosis: > 85 dB, Electrode offset potential: ±300mV, Leakage Current: < 10 uA, Baseline Recovery: < 3 S After Defi, ECG Signal Range: ±8 m V ( Vp-p ):Bandwidth: Surgery: 1 ~ 15 Hz, Monitor: 0.5 ~ 35 Hz, Diagnostic: 0.05 ~ 100 Hz, Calibration Signal: 1 (mV p-p), Accuracy:±5%, ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV, ARR Detecting: Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Alarm: Available Review: Available |
|||||||||||
EHSY | Multi-Para. Patient Monitor | W00001852 |
ECG:Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V),Lead selection: I, II, III, avR, avL, avF, V, ,Waveform: 2 ch,Lead mode: 3 Leads ( R, L, F or RA, LA, LL),Lead selection: I, II, III, ,Waveform: 1 ch,Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto HR and Alarm :Range :Adult: 15 ~ 300 bpm,Neo/Ped: 15 ~ 350 bpm,Accuracy : ± 1% or ± 1bpm,which great,Resolution: 1 bpm,Sensitivity: > 200 (uV P-P),Differential Input Impedance: > 5 MΩ,CMRR:Monitor: > 105 dB,Operation: > 105 dB,Diagnosis: > 85 dB,Electrode offset potential: ±300mV,Leakage Current: < 10 uA,Baseline Recovery: < 3 S After Defi.,ECG Signal Range: ±8 m V ( Vp-p ),Bandwidth:Surgery: 1 ~ 15 Hz,Monitor: 0.5 ~ 35 Hz,Diagnostic: 0.05 ~ 100 Hz,Calibration Signal: 1 (mV p-p), Accuracy:±5%,ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV,ARR Detecting:Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Alarm: Available Review: Available |
|||||||||||
EHSY | SPO2 and TEMP Patient Monitor | W00001850 |
Patient Range: Adult, pediatric, infant, neonate patients SpO2:Measurement range: 35%~100%,Accuracy: ±2%(70%~100%) ,0%~69% unspecified,Resolution: 1% Pulse Rate:Measurement range:30 bpm -250 bpm,Accuracy:±2bpm,Resolution:1bpm Temperature (TEMP):Channel: 1,Input: Body surface thermal-sensitive resistor temperature sensor,Measurement range:0 oC~50℃,Accuracy:±0.2℃,Resolution:0.1℃ |
|||||||||||
EHSY | SPO2 and TEMP Patient Monitor | W00001849 |
Monitoring Parameters: SpO2、PR、PLETH、Pulse strength、TEMP Signal sockets:SpO2 socket、PR socket、TEMP socket、adaptor socket、PC communication socket Type: 128×64 dot matrix homochromy LCD Display area: 45mm×30mm |
|||||||||||
EHSY | SPO2 and TEMP Patient Monitor | W00001848 |
Monitoring Parameters: SpO2、PR、PLETH、Pulse strength、TEMP Signal sockets:SpO2 socket、PR socket、TEMP socket、adaptor socket、PC communication socket Type: 128×64 dot matrix homochromy LCD Display area: 45mm×30mm |
|||||||||||
EHSY | NIBP and SPO2 Patient Monitor | W00001843 |
NIBP: Patient: Adult and Pediatric, Measurement method: Oscillometric, Range: Adult: 30mmHg~255mmHg Pediatric: 30mmHg~160mmHg, Measurement unite: mmHg/kPa selectable, Measurement mode: Manual, Auto, STAT, Measurement Type: SYS, DIA, MAP, Measurement interval in AUTO mode:1,2,3,5,10,15,20,30,45,60Min, Measuring period in STAT mode: 5 Min, Resolution:1mmHg, Over-pressure protection:Adult: 300mmHg Pediatric: 220mmHg SPO2: Patient: Adult, child, Range: 0 -100%, Resolution: 1 %, Accuracy: ±2 %(90~99%), ±3 %(70~89%),unspecified (<70%) PR: Range:30bpm~250bpm, Resolution:1bpm, Accuracy: ±2bpm Temperature: Channel: 1, Input: Body surface thermal-sensitive resistor temperature sensor, Measurement Unit: °C/°F selectable, Range: 0~50℃, Resolution: 0.1℃, Accuracy: ±0.1℃ |
|||||||||||
EHSY | NIBP and SPO2 Patient Monitor | W00001842 |
Size: 205mm×200mm×95mm Weight: 1 kg Parameter Display: 7-segment LEDs Information Display: Fixed characters and icons lighted by single-color LEDs |
|||||||||||
EHSY | Handheld Multi-Para. Patient Monitor | W00001840 |
ECG: Input:3-core ECG cable, standard AAMI cable connector, Lead selection:I, II, III, Gain selection: X1, X2, X4, X8, None filter: 0.05~100Hz (-3dB), Filter: 0.5~40Hz (-3dB), Scan Speed: 12.5, 25, 50 mm/S, ECG standard signal: 1mV square wave generated by hardware Heart rate: Measure range: 20~250 bpm, Renew time: 1 time per beat, Accuracy: 1 bpm, Alarm limits range: Upper limits 80~250bpm, Lower limits 40~100 bpm, Alarm mode: Audible and visual alarm NIBP: Measure Method: Automatic oscillometric, Average measure time: <40 seconds, Repeat Cycles: 1, 2, 3, 5, 10, 15, 20, 30, 60 minutes, Alarm limits range: SYS : Upper limits 120~250 mmHg, Lower limits 60~180 mmHg, DIA : Upper limits 80~150 mmHg, Lower limits 40~120 mmHg, MAP : Upper limits 100~230 mmHg, Lower limits 50~160 mmHg SpO2 : Measure Range: 35~100%, SpO2 Accuracy: 2%(70~99%), 3%(40~70%), Pulse, Rate Range: 0~254 bpm, Pulse Rate Accuracy: 1 bpm, Alarm limits range:SpO2 upper limits : 95~99%, lower limits: 85~96% |
|||||||||||