Brand | Product Name | EHSY Item# | Description | List Price(USD) | ||||||||||
EHSY | Calorimeter (Single Control) | W00005356 |
Single Complete Testing Duration: <11min Stability: Heat Capacity Variation in 3 months: ≤0.20% Accuracy: The mean value and standard value deviation is less than 50J/g after 5 caloric value test of benzoic acid. Temperature Resolution: 0.0001K |
|||||||||||
EHSY | Calorimeter (Double Control) | W00005355 |
Single Complete Testing Duration: <11min Stability: Heat Capacity Variation in 3 months: ≤0.20% Accuracy: The mean value and standard value deviation is less than 50J/g after 5 caloric value test of benzoic acid. Temperature Resolution: 0.0001K |
|||||||||||
EHSY | Calorimeter Single Control) | W00005354 |
Single Complete Testing Duration: <13min Stability: Heat Capacity Variation in 3 months: ≤0.20% Accuracy: The mean value and standard value deviation is less than 50J/g after 5 caloric value test of benzoic acid. Temperature Resolution: 0.0001K |
|||||||||||
EHSY | Calorimeter (Double Control) | W00005353 |
Single Complete Testing Duration: <13min Stability: Heat Capacity Variation in 3 months: ≤0.20% Accuracy: The mean value and standard value deviation is less than 50J/g after 5 caloric value test of benzoic acid. Temperature Resolution: 0.0001K |
|||||||||||
EHSY | Calorimeter (Single Control) | W00005352 |
Single Complete Testing Duration: <15min Stability: Heat Capacity Variation in 3 months: ≤0.20% Accuracy: The mean value and standard value deviation is less than 50J/g after 5 caloric value test of benzoic acid. Temperature Resolution: 0.0001K |
|||||||||||
EHSY | Calorimeter (Double Control) | W00005351 |
Single Complete Testing Duration: <15min Stability: Heat Capacity Variation in 3 months: ≤0.20% Accuracy: The mean value and standard value deviation is less than 50J/g after 5 caloric value test of benzoic acid. Temperature Resolution: 0.0001K |
|||||||||||
EHSY | Calorimeter (Single Control) | W00005350 |
Single Complete Testing Duration: <17min Stability: Heat Capacity Variation in 3 months: ≤0.20% Accuracy: The mean value and standard value deviation is less than 50J/g after 5 caloric value test of benzoic acid. Temperature Resolution: 0.0001K |
|||||||||||
EHSY | Calorimeter (Double Control) | W00005349 |
Single Complete Testing Duration: <17min Stability: Heat Capacity Variation in 3 months: ≤0.20% Accuracy: The mean value and standard value deviation is less than 50J/g after 5 caloric value test of benzoic acid. Temperature Resolution: 0.0001K |
|||||||||||